The most likely fix on a Jandy heater code: check flow before you touch the heater. The message we see most on South Florida JXi heaters is CHECK FLOW, and Jandy's own manual lists four causes for it: a pump that isn't running, low pump pressure, a variable-speed pump set too low, or a faulty pressure switch. Three of those four live outside the heater. The other message worth knowing by name is FAULT-CHECK IGN CONTROL, a failed light-off that belongs with a licensed tech. Wording varies by manual revision, and the older LXi uses slightly different messages, so match your display against your heater's manual.
I've been on Florida pool routes since the late 1990s, and the pattern on Jandy heaters has held the whole time: the heater reports the problem honestly, and the problem usually sits upstream of it. The code meanings below come from Jandy's installation and operation manuals for the JXi, LXi, JE, and VersaTemp. The order we check things in is ours.
How a Jandy heater reports a fault
A JXi or LXi reports a problem two ways. The front display prints a message in words. Inside the cabinet, the ignition control board has an LED that flashes a count. If you searched for a “Jandy heater service light,” the display message is what you read first. The flashing LED is the light Jandy documents for ignition faults, and it sits behind a panel you shouldn't be pulling on a gas appliance.
Jandy JXi and LXi error-code quick reference
| Display message | What it means | Likely cause | DIY or pro? |
|---|---|---|---|
| CHECK FLOW (JXi), NO FLOW (LXi), FAULT-PUMP NO FLOW (older JXi) | The water pressure switch isn't seeing enough flow, so the burner won't fire | Pump not running, low pump pressure, variable-speed pump set too low, or a faulty pressure switch | Pump, filter, and valves are DIY; the switch is pro |
| FAULT-PUMP | Current JXi: a status message, not a failure — the filter pump is off while the heater is in Maintain Temp mode. LXi: the pump isn't running | JXi: normal, and Jandy says no service is required. LXi: a breaker, wiring, or the time clock | DIY |
| FAULT-HIGH LIMIT | Water in the heater exceeded its internal limit, or a limit switch faulted | Whatever is overheating the water (check flow first), a limit switch, or a loose connection | Flow is DIY; the rest is pro |
| FAULT-HIGH FLUE TEMPERATURE | JXi: the flue temperature limit tripped | An obstructed vent or a failed flue sensor | A look from outside is DIY; the sensor is pro |
| FAULT-CHECK IGN CONTROL (older JXi: FAULT-CHECK IGNITION STEPS) | The ignition sequence failed | Air pressure switch tubing, combustion fan, restricted air, broken igniter, low gas pressure or volume, no flame, or wiring | Pro — gas |
| FAULT-SHORTED H2O SENSOR or FAULT-OPEN WATER SENSOR | The water temperature sensor reads shorted or open | A failed sensor or a bad connection at the power interface board | Pro |
| FAULT-FUSELINK/FIELD (LXi and older JXi) | A fault in the fusible link or field wiring circuit | A fusible link fault or a loose connection | Pro |
CHECK FLOW: the message that is usually your filter
Every JXi has a water pressure switch that won't let the burner fire without circulation, and CHECK FLOW is that switch reporting it never closed. Jandy specifies at least 30 gallons per minute through the heater, up to a 100 gpm maximum, and warns that flow under 30 gpm can cause nuisance operation and even damage the heater. Jandy's remedy list for this message, in order: breakers, wiring, and the time clock; a dirty filter, a blockage, or a valve in the wrong position; return eyeball fittings missing from the pool wall; adjusting or replacing the pressure switch; and turning up a variable-speed pump.
That last one is the South Florida special. Nearly every pad we service runs a variable-speed pump now, and a pump dialed down for savings may not push 30 gpm through the heater when it calls for heat. Raise the speed during heating hours before anyone suspects the switch. If the switch does need adjusting, that's a tech job — Jandy's procedure has the side panel off and the heater running.
FAULT-CHECK IGN CONTROL and the LED flash count
This is the light-off failure, and Jandy's cause list covers air and gas alike: split, pinched, or disconnected air pressure switch tubing; a combustion fan that won't run or runs slow; restricted air at the intake or discharge; a broken igniter; low gas pressure or volume; no flame; and loose wiring. On the LXi, Jandy adds oscillating pump pressure, fixed by cleaning the filter — the one homeowner check on this message.
A tech narrows it down with the LED on the ignition control. Jandy's LED codes read the same on the JXi and the LXi:
- LED on steady: ignition control fault.
- One flash: air flow fault — tubing, fan, or a restriction at the intake or discharge.
- Two flashes: flame exists when there is no call for heat. Jandy says to refer it to qualified service, and I'd leave the heater off until a tech has looked at it.
- Three flashes: ignition lockout — three failed tries to fire. Jandy calls it a soft lockout.
Past the LED it's gas work. Jandy specifies inlet gas pressure of 4.0 to 10.5 inches of water column on natural gas and 4.0 to 14.0 on propane, read with a manometer while the heater is firing — Jandy warns that a reading taken with the heater off can mislead. The manual also says gas valve failures are extremely rare and that the valve should be replaced only after it's confirmed as the root cause. If someone wants to sell you a gas valve first, ask what they measured. When the supply line is the problem, see our gas heater line sizing guide.
FAULT-HIGH LIMIT and FAULT-HIGH FLUE TEMPERATURE
FAULT-HIGH LIMIT means water inside the heater got hotter than its internal limit, or a limit switch faulted. Water overheats in a heater when it isn't moving through fast enough, so flow is the first look here too. Once flow is confirmed good, Jandy's LXi guidance is to verify the high limit switches, run a temperature rise test, and find the cause of the overheating — licensed work.
FAULT-HIGH FLUE TEMPERATURE is a JXi message: the flue temperature limit tripped. Jandy's remedy starts with inspecting the vent for obstructions — on indoor installs it specifically calls out bird, insect, and rodent activity in the vent pipe — and then replacing the flue sensor. A look at the top of the heater from outside is yours. The sensor isn't.
Fix before you call: the homeowner sequence
- Write down the exact message. Photograph the display and note whether you have a JXi or an LXi — the wording differs.
- Confirm the heater is being asked to heat. Control in POOL or SPA, set point above the current water temperature — Jandy's own first check before service.
- Clean the filter and empty the baskets. A loaded filter is the most common reason a heater can't see flow.
- Walk the pump and valves. Pump running, time clock or automation set correctly, valves to the heater open, return eyeball fittings in the pool wall, and a variable-speed pump fast enough to move 30 gpm through the heater.
- Clear around the heater. Jandy wants the top, underneath, and surrounding area free of leaves and combustible debris, and the combustion air openings unblocked.
- Confirm gas at the source. The main gas valve outside the heater jacket open, and on propane, a tank that isn't empty.
- Restart once. If the same message comes back, stop. Resetting the same fault over and over isn't diagnosis.
One rule overrides the list, and it matters in hurricane country: if any part of the heater has been under water, Jandy says not to use it until a qualified technician has inspected it and replaced any affected control or gas control parts.
Jandy JE and VersaTemp heat pump faults
Jandy's JE and VersaTemp manuals carry the same diagnostic table, and the display holds a fault until the problem is resolved.
- FAULT-NO FLOW. Low or restricted flow — an external bypass valve in the wrong position or a malfunctioning flow switch. Pump running, valves set, filter and skimmers clean, water level up, and any fountain or waterfall that bypasses the heat pump inlet temporarily shut off.
- FAULT-HIGH REF PRESSURE. Head pressure opened the high pressure switch. Jandy's fix is a flow fix: pump on, valves open, filter and skimmers clean, and a higher speed on a variable-speed pump. Cycle the unit off and on up to three times before you call.
- FAULT-LOW REF PRESSURE. Suction pressure dropped, which Jandy notes can happen when the air is cold. Check that the fan runs and air comes out the top.
- FAULT-HIGH WATER TEMP. A safety shutoff when the water reaches the maximum allowed temperature, unless the unit is in chiller mode.
- COIL SENSOR or WATER SENSOR faults (shorted or open). A sensor failed or came disconnected, and the control shuts the heat pump off.
Both manuals also mention a five-minute delay countdown, so a unit that won't start right after it's switched on may simply be waiting it out. Anything past the flow and fan checks is refrigerant or electrical work, and refrigerant work requires an EPA-certified technician.
South Florida failure modes
- Storm debris. One storm can pack the baskets and load the filter at once, which produces CHECK FLOW on a JXi and FAULT-NO FLOW on a JE from a single cause.
- Critters in the vent. Jandy calls out birds, insects, and rodents in vent pipes. On outdoor Florida pads we find wasp nests and spider webs in heaters that sat idle all summer.
- Water chemistry. Jandy's JXi warranty doesn't cover heat exchanger damage from corrosive water, and the LXi warranty excluded scaling that restricts flow. Balanced water is the cheapest heater insurance on the pad.
What repairs cost, and when to replace
Most heater repairs we quote land between $250 and $1,800. A heat exchanger, or a compressor on a heat pump, runs $4,000 to $5,000, and at that number a new heater at $5,000 to $7,000 installed is usually the better buy on an older unit. A diagnostic visit runs $0 to $125, and it's free for our weekly-route clients.
When to call a pro
Flow, valves, the filter, the baskets, and the gas supply valve outside the heater are yours. Everything inside the cabinet — the LED read, igniter, air pressure switch, sensors, limit switches, and gas pressure under load — is licensed work. We manage heater repairs across Palm Beach and Broward under our Florida Certified Pool/Spa Contractor license, doing most of the work ourselves and bringing in a licensed gas contractor for gas line work, or an electrician when a job needs a new circuit. Start with our pool heater repair service, or work the brand-neutral checklist in our pool heater troubleshooting guide first. Running a different brand? See the Raypak, Pentair MasterTemp, and Hayward code guides.
Frequently asked questions
CHECK FLOW means the heater's water pressure switch is not seeing enough circulation, so the burner will not fire. Jandy lists four causes: the pump is not running, pump pressure is low, a variable-speed pump is set too low, or the pressure switch is faulty. Jandy specifies at least 30 gallons per minute through the heater. Check the breaker and time clock, clean the filter, empty the baskets, open the valves to the heater, and raise the pump speed before anyone touches the pressure switch. On an LXi the same condition reads NO FLOW.
It means the ignition sequence failed. Jandy's cause list includes broken, split, pinched, or disconnected air pressure switch tubing, a combustion fan that is not running or runs slow, restricted air at the intake or discharge, a broken igniter, low gas supply pressure or volume, no flame at the burner, and loose wiring. On the LXi, Jandy also lists oscillating pump pressure, which a clean filter can fix. Past that one check, this is gas work for a licensed technician, starting with the LED code on the ignition control board.
The ignition control board inside a JXi or LXi has an LED. On steady means an ignition control fault. One flash is an air flow fault. Two flashes means flame exists when there is no call for heat, which Jandy says to refer to qualified service. Three flashes is an ignition lockout after three failed attempts to fire, which Jandy calls a soft lockout. The LED sits inside the cabinet of a gas appliance, so reading it is a job for a technician.
On a JXi or LXi, faults show up as words on the front display, such as CHECK FLOW or FAULT-HIGH LIMIT. The flashing light Jandy documents for ignition faults is the LED on the ignition control board inside the cabinet. Read the display message first, write it down, and work the flow checks before calling. The LED read belongs to a technician because it means opening a gas appliance.
Water inside the heater got hotter than its internal limit, or a limit switch faulted. Water overheats in a heater when it is not moving through fast enough, so check flow first: pump running, filter clean, valves open. If flow is good and the fault repeats, Jandy's guidance is to verify the high limit switches, run a temperature rise test, and find the cause of the overheating, which is work for a licensed technician.
On a current JXi, FAULT-PUMP is a status message, not a failure. Jandy says it appears when the filter pump is off while the heater is set to Maintain Temp mode, and no service is required. On an LXi, it means the pump is not running, so check the breaker, the wiring, and the time clock.
Jandy's JE and VersaTemp manuals share one table. FAULT-NO FLOW is low or restricted flow, from a bypass valve in the wrong position or a malfunctioning flow switch. FAULT-HIGH REF PRESSURE means head pressure opened the high pressure switch, and Jandy's fix starts with flow: pump on, valves open, filter and skimmers clean, and a higher speed on a variable-speed pump. FAULT-LOW REF PRESSURE means suction pressure dropped, which can happen in cold air, so check that the fan runs. FAULT-HIGH WATER TEMP is a safety shutoff, and the coil and water sensor faults mean a sensor failed or came disconnected. Refrigerant work requires an EPA-certified technician.
Not until it has been inspected. Jandy says not to use the heater if any part of it has been under water, and to have a qualified technician inspect it and replace any affected control or gas control parts. In South Florida that means any heater on a pad that flooded during a storm gets checked before it is switched back on.
Most heater repairs we quote run $250 to $1,800. A heat exchanger, or a compressor on a heat pump, runs $4,000 to $5,000, and at that point a new heater at $5,000 to $7,000 installed is often the better buy on an older unit. A diagnostic visit runs $0 to $125 and is free for our weekly-route clients. Before any of that, clean the filter, because a CHECK FLOW message often ends there.
Jandy still showing a fault after the flow check?
Most CHECK FLOW messages end at the filter. If yours didn't, we diagnose Jandy JXi, LXi, and JE units across Palm Beach and Broward — flat-rate quote in writing before any part is ordered.